1.
J Trauma Acute Care Surg ; 94(5): 718-724, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36749658

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a lifesaving therapy for hemorrhagic shock following pelvic/lower extremity injuries in military settings. However, Zone 1 aortic occlusion (AO; above the celiac artery), while providing brain/cardiac perfusion, may induce/worsen visceral ischemia and organ dysfunction. In contrast, AO Zone 3 (below the renal arteries) provides abdominal perfusion potentially minimizing ischemia/reperfusion injury. We hypothesized that, compared with AO Zone 1, AO Zone 3 provides neuro/cardioprotection while minimizing visceral ischemia and reperfusion coagulopathy after severe traumatic hemorrhage due to pelvic/lower extremity injuries. METHODS: Fifty-kilogram male Yorkshire swine underwent a blast polytrauma injury followed by a resuscitation protocol with randomization to no AO (No AO, n = 6) or AO with REBOA at Zone 1 (AO Zone 1; n = 6) or Zone 3 (AO Zone 3; n = 4). Vital signs and intracranial pressure (ICP) were monitored for 240 minutes. Citrate native and tissue plasminogen activator challenge thrombelastography, prothrombin time, creatinine, lipase, total bilirubin, troponin, and enzyme-linked immunosorbent assays protein levels were measured at set intervals. RESULTS: Both AO groups had significant increases in mean arterial pressure during aortic occlusion. All three groups had significant increases in ICP, but final ICP in the No AO group (26 ± 5.8 mm Hg) was significantly elevated compared with AO Zone 1 (17 ± 5.2 mm Hg) and AO Zone 3 (16 ± 4.2 mm Hg) ( p < 0.01). The final mean troponin in the No AO group (4.10 ± 5.67 ng/mL) was significantly higher than baseline (0.03 ± 0.02 ng/mL, p < 0.05), while the two AO groups had no significant changes ( p > 0.05). AO Zone 1 was the only group associated with hyperfibrinolysis ( p < 0.05) and significantly increased prothrombin time ( p < 0.05). Only AO Zone 1 group had significantly higher markers of organ damage. CONCLUSION: Compared with AO Zone 1, AO Zone 3 provided similar neuro/cardioprotection but with less organ dysfunction and coagulopathy. This study suggests that Zone 3 REBOA may be preferable over Zone 1 for treating military relevant blast polytrauma with minimal intra-abdominal and chest trauma, but further clinical investigation is warranted.


Assuntos
Oclusão com Balão , Transtornos da Coagulação Sanguínea , Procedimentos Endovasculares , Traumatismo Múltiplo , Choque Hemorrágico , Masculino , Animais , Suínos , Ativador de Plasminogênio Tecidual , Insuficiência de Múltiplos Órgãos , Aorta , Choque Hemorrágico/complicações , Choque Hemorrágico/terapia , Ressuscitação/métodos , Reperfusão , Transtornos da Coagulação Sanguínea/etiologia , Transtornos da Coagulação Sanguínea/prevenção & controle , Traumatismo Múltiplo/complicações , Traumatismo Múltiplo/terapia , Isquemia , Oclusão com Balão/métodos , Circulação Cerebrovascular , Procedimentos Endovasculares/métodos , Modelos Animais de Doenças
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA